To Enter Boost Mode Press and Hold Temperature Button 10 Seconds, Here is an excerpt from page 423 (892)[6] of their 2019 catalog:[7], "This Jandy Limited Warranty does not apply to Jandy branded products purchased through the Internet or other e-commerce platforms, with the exception of Jandy branded valves, parts, and accessories. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. good documentation. We will contact you as soon as this product is available. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual. JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000, This product has a 1 year warranty from the manufacturer. If the salinity is above 4.0 gpl, the unit will cut off and give error code 145 (High Salinity). The PureLink DC Cord is Jandy P/N R0402800. Page 17 in the Jandy Power Center Installation Manual shows the location of the jumper. ORP / External Control Interface 2. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. See Section 6.5 of the owner's manual, Winterizing. 2023 Zodiac Pool Systems LLC - All rights reserved. This can usually be prevented by sealing the stone with a sealer. Manufacturer SKU: 6967+. The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. $669.99 $ 669. Free Shipping and more for Pool Perks members. Looks like your current store isn't near your delivery area. Search in reviews, Q&A. If the unit reads 2.8 gpl for salinity, then the unit has not been recalibrated. Polarity will change every 3 hours. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. $200 later guy said unit was shipped without a translatetor card???? A member found that the new part fit perfectly with the same mounting holes. Available in 7 or 14-blade configurations. From the Jandy controller, you can see the salt PPM, and you get a menu for setting the production rate percent for pool and spa modes - perfect. No instructions contained w/unit. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. ORP / Freeze Control Unit 3 . Water conditioning salt pellets are compressed forms of evaporated salt and may be used. In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. All Rights Reserved. The systems are comprised of the following components: Arrived sooner than promised. Do Not use calcium chloride as a source of salt. These control pool and spa combinations sharing one set of equipment (Actuators included). Jandy / Zodiac PLC1400 Replacement Cell Kit for AquaPure / PureLink 1400. This issue is with the trisensor, which is a separate part that installs in the cell. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. Can this be used to replace an old Aquapure 1400 control box? Rely on its sturdy design and simple features to create your saltwater oasis. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. $299.99. This difference in readings started about 1 week ago. So it looks like it is good, but the water temp sensor is bad. Set Boost mode and allow to run for 24 hours. Had to replace our original, 14 year old system which developed a front board issue. Super Chlorinate Pool. If chlorine output at the lowest setting consistently provides for excessive chlorine levels, decrease daily pump operation time as much as necessary. See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. This method would require the purchase of 4 unions. The production cycle time used for chlorine production (observationally) is 30 minutes. Leslie's Pool Supplies does not share or sell personal info. (Use sodium chloride only). That picture was after Snowmageddon. Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. Integrates very well with Aqualink. 2023 Zodiac Pool Systems LLC - All rights reserved. Free shipping for many products! Rely on its sturdy design and simple features to create your saltwater oasis. If one of them is rotted away, it's time for a new cell and cord. Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Recheck. Please consider. You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. Check Cell studs for same. If not, contact a pool professional. Jandy Pro Series AquaPure Power Pack AquaPure Salt Chlorinator Models Sanitizer Type Body Material Chlorine Connections Input Current Output Pool Size Recommended Flow Rate Maximum Pressure Recommended Tablets Chamber Capacity of Chlorine AquaPure Power Pack and PureLink Cell Kit, 7 Blade #PLC700 Saltwater Chlorinator PPGF inground with iAqualink remote control. 3.9 out of 5 stars 35. For very hard water, some chlorinators can shorten the polarity inversion time (e.g. Being relatively adept, I chose to install this myself. Low salt concentration below 2.0 gpl will cause premature cell failure. Most common is the center pin.[9]. Shop Online or at any of our 900+ retail stores! Why You Should Only Work With A Qualified Professional. You will also find the cell sold alone at a lower price then the kit and it is tempting to buy only the cell. Press and hold the test buttons marked salinity and R-temp. No instructions contained w/unit. This AquaPure foundation power center pack is designed to se with Zodiac Jandy AquaPure PureLink cell kit. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. After installing began to flash code of 181 & 172. Increase chlorine production by pressing the Chlorine Production Rate Adjustment button (arrow button B). Error posting question. Find many great new & used options and get the best deals for E1 Jandy PLC1400 AquaPure 3-Port Salt Water Pool System at the best online prices at eBay! To avoid clogging the filter or damaging the control center and pump, do not add salt through the skimmer, main drain, or surge tank. Sign up now. IS this the complete system? The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. The air temp went up. Remove and clean flow/temp/salinity sensor contacts. It may not display this or other websites correctly. It should use the Air temperature sensor. Jandy no longer supports parts for their older systems. Register product at Jandy.com/registration. Please select a nearby store with available inventory to process your order. When replacing the cell, it's important to replace the power cord so that the connections are clean and the resistance is minimized.[3]. If still too low, Super Chlorinate with outside source. For all your hard to find pool and spa parts, including above ground spa parts, The three pins go inside and connect to the plates. We paired it with the APUREM. This corrosion increases the resistance of the connection and generates a lot of heat due to the high current of 6 to 8 amps. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. Also look inside the cell at the cord end. Changes to Aquapure settings made on Aqualink will not show on the Aquapure and the chlorine% will be 0. Had to call a pool guy. If there is still a large amount of bromide in your pool, we recommend that you wait for it to dissipate. Reviewed in the United States on December 6, 2014. All other forms of chlorine (tablets, powder, liquid, etc.) In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. The cell cannot be repaired even though the plates may have life left in them. The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. Apple is not a participant or sponsor of this promotion. You know what? Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Very happy with seller. with the pool water. Guess we will this year.
2 - Screws, Power Interface. The Jandy tri-sensor measures water flow, salinity, and water temperature. Zodiac Jandy iAquaLink 2.0 Wireless Network Pool Control Interface Sys. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Dilute pool with fresh water. The sensor connects to the same spot. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. You need the Aquapure system with the control box and cell. See Section 4.7 of the owner's manual. I bought one of these units from another vendor three years ago. Add stabilizer to maintain 50 - 75 PPM per pool professionals recommendations. If there's a little adapter card between the old sensor cord and the circuit board, remove the adapter card. This action maintains the cell. Pricing and offers are subject to change. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Polarity Inversion is what salt water chlorinators use to periodically remove scale from the electrode plates. If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. Please obtain a google maps API key and put it in Site Preferences! It includes aquapure control box only. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. That is NOT what you have. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). Many of these units have been shipped with bad circuit boards, as my pool professional was told by the Jandy tech. Apple is not a participant or sponsor of this promotion. Sitemap | Either a short wait or a reboot resolve this. You can check the calibration by doing the following below procedure. The PLC1400 cell is Jandy P/N R0452400. No Flow indicator stays on continuously. Add To Cart. Amazon has encountered an error. Please try again. They are sold as a kit.[2]. Unit came with panel knocked out and the circuit board was bad. . The LCD should read 2.8 gpl*. Use Up and Down arrow keys to navigate search results. ORP / External Control Interface 2. They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. See Section 5, Operating Instructions of the owner's manual. You need to determine the correct Revisio, Q: Ideas on how to resolve this issue? Find a Dealer AquaPure Salt Water Pool System Downloads Document ID SL6605 Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. VERY GOOD PRODUCT, indeed, easy to install. Do Not use Rock salt (insoluble impurities mixed with the rock salt can shorten the life of the unit). This product hasn't received any reviews yet. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. Does the Freeze Protect mode use the reading from the tri-sensor or the pool temperature sensor? Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. Can I switch from bromide to salt water chlorination using the same water? Use a salt that is at least 99.8% pure NaCl. There are numerous sites that have detailed information about the install. Check for correct operation of the pump. If corrosion appears in one year, it can be explained by incorrect water chemistry or bonding issue, not by the presence of salt alone. (Take pool water sample to Pool Professional). You must log in or register to reply here. It's usually cheaper to buy the Aquapure 1400 cell kit that comes with the cell, trisensor and power cord vs. buying the parts separately. eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . >PoolAndSpaPartsDepot.com is Open for Business! When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. JavaScript is disabled. Need to, Your zip code will help us to provide you with the most up-to-date delivery information. Rely on its sturdy design and simple features to create your saltwater oasis. Filter, Hayward Star-Clear Cartridges C-250 thru C-1750, Hayward Swim Clear Large Capacity Cartridges, Pentair Purex Bottom Manifold Filter Grids, Pentair Replacement Cartridges QUAD Filters, Filter Backwash Valves, Diverter Valves, Check Valves, Hayward Navigator - PoolVac Cleaner Parts, Pool Control Systems and Automation Parts, Aquarite Cell Replacements - Above Ground, Hayward Aquarite Goldline Parts, Sensors, Boards, Jandy Zodiac Salt Cell PLC1400 Aquapure1400 PureLink Cell Kit 40K, Jandy PLC700 PureLink 7-Blade Salt Generator Cell Kit, Hayward Salt & Swim 3C Control Unit Only W3SAS-PRO, Hayward Salt & Swim 3C Replacement Salt Cell W3SAS-CELL, Pentair IntelliChlor Salt Generator Above Ground Pools IC15 EC-520888, SmartSalt Salt Chlorine Generator 25K 25,000 Gallons, Hayward AquaTrol RJ Salt Chlorine Generator W3AQ-TROL-RJ, Pentair Intellichlor IC60 Salt Water System 521105 and 520556. One method is an additional PVC union after each end of the cell. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. While the salt shouldn't have any effect on the person if a small amount is swallowed, please keep in mind that the water is chlorinated and chlorine should not be consumed. What is polarity inversion on a salt water chlorinator? Press the Salinity button and hold it until it beeps 3 times. If so, why the 2 different readings? This is related to the serial com connections that are used. Apple is not a participant or sponsor of this promotion. Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 . Plug flow/temp/salinity sensor into connector on power center printed circuit board. It measures temperature, salinity and flow. If the chlorinator is the correct size, then it's sufficient to sanitize the pool without adding granular chlorine. Make sure that temp is above 60, salt is 3400, power cord is good and look in the cell at the plates with a good light from both ends to see if the plates are corroded. You can usually see evidence of a leak when you know to look for it. We evaluated 6535 medical consults of intoxication cases involving prescription and over-the-counter drugs in 2001. Asked on 5/16/2017by Steve. Being relatively adept, I chose to install this myself. Thank you for your business! Look for heavy corrosion at both ends. Verify salinity with Myron L meter calibrated for NaCl, titration test units, or other salt meters. Measures 6-inch diameter by 14-inch width by 9-1/2-inch height. In Store Only. PLASTIC CONTROL CENTER, MODELS 700 & 1400, PARTS - BIG DIPPER, ECLIPSE, TOTAL ECLIPSE, COMPLETE HIGHCAPACITY BROMINE & CHLORINE FEEDERS, KREEPY E-Z VAC & KREEPY KADET ACCESSORIES, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, AMERICAN PRODUCTS 5 & 8 POSITION TOP MOUNT, SPA DRAIN & ON/OFF VALVES FOR GARDEN HOSE, STANDARD HEATER UNION COMPONENTS - 1", 200 SERIES TYPHOON JETS - SCALLOPED, 2" FACE, 300 SERIES TYPHOON JETS - SCALLOPED, 3" FACE, 400 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, 500 SERIES TYPHOON JETS - SCALLOPED, 5" FACE, RETRO FITTING LEN GORDON & OTHER CONTROLS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, 200 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, JANDY AQUAPURE | CONTROL BOX, PURE700 | R0402900, JANDY AQUAPURE | UNION NUT, 2" BLACK | R0412500, JANDY AQUAPURE | SALINITY METER | R0475300, JANDY AQUAPURE Ei | TS CONTROL PCB ASSY | R0512300, JANDY AQUAPURE | SPOOL PIECE, 2" BLACK UNIONS W/2803-009 | R0412800, POLARIS OZONATORS | 110/220V FOR UP TO 40,000 GALLONS | PZVII-2 | Discontinued, PENTAIR | HC-3330 HOUSING W/ 2098-0 | R172437, Pool and Spa Parts Depot | Swimming Pool Supplies. This site is protected by reCAPTCHA and the Google. Scale formation on pool equipment. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Recieved and installed myself. You are dealing with 240 Volts and electrical circuits. Will salt from the salt water chlorinator deteriorate the metal components in my pool? Work the first time without any issue or abnormal event. High salt concentration above 4.0 gpl may damage the power center. You can check the amperage to verify if the cell is generating. I bought one of these units from another vendor three years ago. Earn at least $9 in pool perks for this item by joining Pool Perks. 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. Learn more. * Pricing, promotions and availability may vary by location and at lesliespool.com. Haha! (567 gm/24 Hr.). Pool or Spa Only Controls are for use with single body pool or spa utilizing one set of equipment. 2 for when the cell is installed and 1/2 of the other 2 unions (the "male" 1/2) for creation of the bypass pipe. Jandy AquaPure Control Center Parts |6 parts Frequently Purchased AquaPure Sanitizer Bottom Control Box Decal - R0404400 6 in stock $65.70 Add To Cart AquaPure Transformer - 115/230 Volts - R0481400 12 in stock $434.61 Add To Cart Control Box Cover, Pure1400 - R0403200 Allow 7-10 Days to Ship $185.91 Add To Cart Pure700 Control Box Cover - R0403100